A completed two-story barndominium with visible second-story windows and a small covered balcony above the entry porch.

2-Story Barndominium in Tennessee

A second storey is a full floor plate over the ground floor. That is a different thing from a loft, which is an intermediate level open to the room below and counted as part of the storey beneath it. The reason to build one is straightforward: the foundation and the roof are two of the most expensive assemblies in a barndominium and both are priced by footprint, so splitting a given total across two levels stops both of them growing. What you pay for it is a stair that takes floor area out of both levels, a floor structure that has to span the same distance the roof does, and a load path that carries the upper floor down through a frame otherwise sized for roof load alone. One thing that does not motivate it here: none of the twenty Tennessee jurisdictions behind this site imposes a minimum heated floor area on a site-built dwelling, so stacking is not a route past a size rule. What it does run into is height, storey count and setbacks. Unincorporated Hamilton County allows two and a half stories or 35 feet. Maury County's RG district allows two storeys. Loudon County adds five feet to the required side yard for every storey above the first.

What actually changes with this feature

The look is the easy part. These are the decisions that follow from it.

Where the prescriptive path stops

In the Tennessee 2018 IRC, Table R502.3.1(2) tops out at 23 ft 3 in for a 40 psf living-area load and Table R502.3.1(1) at 25 ft 7 in for a 30 psf sleeping-area load, both on a 2x12 select structural joist at 12-inch centres carrying 10 psf dead load. A 40 ft clear span sits roughly 70 per cent beyond the living-area figure, so there is no prescriptive dimensional-lumber second floor for this building type. R301.1.3 then applies to the floor exactly as it already does to a clear-span roof, and R301.1.3 keeps its number in the 2018, 2021 and 2024 editions, so the citation holds whichever edition your jurisdiction is on. The code names alternatives rather than banning the span: prefabricated I-joists and structural glued laminated timber under R502.1, wood trusses under R502.11, cold-formed steel floor framing under R505.

The second floor changes the structure under it

Every column now carries roof load plus floor load, so the point load at each base grows and the footings under a two-storey clear-span frame are not the footings under the same building at one storey. Cumberland County writes that into its own published expectations for inspections under the 2018 IRC: minimum footing thickness rises from 8 inches on a single-storey home to 10 inches on a brick or two-storey one, and "Built-in basement and 2-story homes must have blueprints drawn by a registered design professional, with a legend for the windows and doors, for review of egress." The same document requires an engineer's letter for walls above 10 feet tall, which a barndominium sidewall triggers before the second storey is even drawn. All of it is design-stage input, which is also why a single-storey barndominium does not cheaply become a two-storey one later.

Height is the constraint that binds first

A single-storey barndominium rarely reaches its district height cap. A two-storey one can. Unincorporated Hamilton County allows "two and one-half (2 1/2) stories or thirty-five (35) feet in height". Robertson County caps at 35 ft with a footnote permitting "no more than three (3) full or partial stories entirely above grade". Maury County allows three storeys and 35 ft in its AP and RR districts but only two storeys in RG. Knox County's A zone allows three storeys and 35 ft, Loudon County three storeys or 36 ft, Wilson County three storeys or 35 ft, and Metro Nashville states that single-family and two-family dwellings "shall not exceed three stories". At the other end, Williamson County's RP-5 and RD-5 rural districts record maximum height as Not Applicable, and Cookeville's zoning code says building height "is unrestricted, except as provided elsewhere in this Zoning Code and as regulated by the Building Code".

What stacking buys, and what it costs on the lot

Less than people assume in one direction and more in another. There is no size rule to beat: none of the twenty jurisdictions behind this site sets a minimum heated floor area for a site-built dwelling, so a second storey is not a compliance move. Lot coverage rarely binds on acreage either — Rutherford County's AR district caps residential coverage at 20 per cent, but its minimum lot is five acres, so the cap allows tens of thousands of square feet of footprint and never reaches a house. It does bind in Murfreesboro, where RS-15 is a 15,000 sq ft lot at 35 per cent coverage. The cost side is specific and local: Loudon County's A-2 side yard is 20 ft for a single-storey structure plus 5 ft for each additional storey, Cookeville's RS-20 and RS-15 add 5 ft per storey over two, and Washington County's R-1 adds 6 ft per storey for buildings over two storeys.

A completed two-story barndominium with visible second-story windows and a small covered balcony above the entry porch.
The span nobody mentions

The second floor has to span as far as the roof does

In a clear-span building nothing holds the middle up. That is the whole point of the type, and it applies to the floor deck exactly as much as to the roof. The Tennessee 2018 IRC's prescriptive floor-joist tables stop at 23 ft 3 in for a living-area load and 25 ft 7 in for a sleeping-area load, and both are the best rows in their tables: a 2x12 at 12-inch centres, select structural grade, the lightest dead load. A 40 ft clear span is not near the end of that table. It is about 70 per cent past it. So the second floor becomes engineered floor trusses, prefabricated I-joists or structural composite lumber, cold-formed steel floor framing, steel beams that shorten the deck span, or a bearing line down the middle of the building. The last one is the cheapest and it quietly gives back the open ground floor you chose this building type for. Pick which one at design stage, where it is still free.

Common ways to build this

Common configurations we see. Yours does not have to match one exactly — this is a starting point for the conversation, not a catalog.

Primary down, bedrooms up

1,400 sq ft ground floor / 1,000 sq ft second floor

Living, kitchen and the primary suite at grade, secondary bedrooms and a bonus room above. The argument for it is practical rather than stylistic: it keeps the rooms used every day off the stair, which is also the answer if the house has to work in twenty years, and it concentrates the plumbing at grade. The open ground floor is the part that has to be engineered, because the second floor plate is spanning over it. If the plan puts a double-height great room under part of that plate, say so early — in Memphis and Shelby County, whose 2021 IRC amendments address this directly, an opening over 15 per cent of the ground floor area is a large floor opening, and where no perimeter walls sit below it the supporting structure has to be engineered.

Full two-storey residence over an open ground floor

1,200 sq ft ground floor / 1,200 sq ft second floor

The smallest-footprint route to a full-size house, and the configuration where the floor structure decision is sharpest, because the whole upper plate is spanning the clear width. It is also the one place in the target set where a second storey earns a compliance point rather than costing one. The City of Knoxville's Estate Neighborhood district requires a primary structure to meet two of three design tests, and one of the three is that the building "must contain more than one finished floor level". A single-storey metal-clad rectangle at a low pitch meets none of the three; a two-storey version meets one of them outright.

Shop at grade, residence stacked above

1,800 sq ft shop at grade / 1,800 sq ft residence above

Ground floor given over to vehicles, equipment and work, with the whole residence on the upper level. The floor between them is the part that needs attention, because it is both the shop ceiling and the house floor. Loudon County's residential inspection guide states the assembly plainly for its 2018 IRC: half-inch gypsum board on the garage side, five-eighths type X on the ceiling where there is living space above, and a solid wood, metal or 20-minute door. The same guide calls for R-19 in floors over unconditioned space, which is what that deck becomes if the shop is not heated. Worth deciding before the shell is ordered, because it changes the depth of the floor structure.

Two storeys over a lower walkout level

1,200 sq ft per level across three levels

East Tennessee and Plateau terrain, where the site is being cut anyway. Three conditioned levels on one footprint is the most floor area per square foot of ground on this page, and in some places the ordinance helps. Unincorporated Hamilton County grants it in writing: "Where the average slope of a lot is greater than one foot rise or fall in seven feet of distance from the established street elevation of the property line opposite the center of the building an additional story will be permitted on the downhill side of the building." Robertson County counts only stories entirely above grade toward its three-storey footnote. On a genuinely falling lot the honest question is whether the second storey is needed at all, since the lower level often delivers the same area without adding building height and without a deck spanning the full width over open air. Two things to check first: Rutherford County's plans review is triggered by a single-family dwelling with a basement of any type or size, and the slope and depth to rock that make a walkout attractive are the same conditions that make a subsurface sewage system hard to site.

2-Story Barndominium: common questions

7 questions we get asked most often about this footprint. If yours is not on the list, ask it directly.

What is the actual difference between a second storey and a loft?
The code draws the line, not the marketing. The Tennessee 2018 IRC defines a mezzanine or loft as an intermediate level between the floor and ceiling of a storey with an aggregate floor area of not more than one-third of the room it sits in, and it stays open to that room. The same code says in terms that mezzanines complying with Section R325 "shall not be considered as stories". Cross either limit — cover more than a third of the space below, or close it in — and it is a second storey: its own floor plate, its own structure spanning the building, and a storey that gets counted when a zoning ordinance counts storeys. The one-third figure can go to one-half in a dwelling unit fitted with an automatic sprinkler system, which is a local question rather than a statewide one. If you are looking at a plan and cannot tell which it is, the test is simple: is the upper level open to the room below, and is it under a third of that room's area? If either answer is no, price it as a storey.
Does a second storey mean losing the open ground floor?
Not necessarily, but it is the decision the whole design turns on. A second floor plate over a 40 ft clear span is past every row of the Tennessee 2018 IRC's prescriptive joist tables, which stop at 23 ft 3 in for living areas and 25 ft 7 in for sleeping areas even on their best rows. So it gets solved one of five ways: engineered floor trusses, prefabricated I-joists or structural composite lumber, cold-formed steel floor framing, steel beams that shorten the deck span, or an interior bearing line. The bearing line is the cheapest and it puts structure back in the middle of the ground floor, which is the thing a clear-span building was chosen to avoid. Any of the other four keeps the span open and costs more. We would rather put that choice in front of you with the plan than let it arrive as a change during framing.
Can I build single-storey now and add a second floor later?
Treat that as a no unless the building was engineered for it from the first drawing. A second floor changes the column loads, the connections and the footings underneath them, and none of those are reachable once the slab is poured and the frame is up. Cumberland County puts a number on the footing half of it in its own inspection expectations: 8 inches thick on a single-storey home, 10 inches on a brick or two-storey one. If a second storey is a possibility rather than a plan, the useful move is to have the frame and foundation designed for the future load now and defer only the floor system and the finishes. That costs something up front and it is a fraction of retrofitting.
Will a two-storey barndominium fit under my height limit?
It depends on the jurisdiction, on the roof pitch, and on where the ordinance measures from — and all three are worth checking before anything is drawn. Unincorporated Hamilton County allows two and a half stories or 35 feet, Robertson County 35 feet with no more than three full or partial stories entirely above grade, Knox County's A zone three storeys and 35 feet, Loudon County three storeys or 36 feet, Wilson County three storeys or 35 feet, Rutherford County and Sumner County 35 feet, and Maury County only two storeys in its RG district. Metro Nashville caps single-family and two-family dwellings at three stories. Williamson County's rural RP-5 and RD-5 districts record maximum height as Not Applicable. The measurement point matters as much as the number: Blount County measures its 35 feet from the highest natural grade immediately adjacent to the structure, so on a cross-slope lot the uphill side is the datum and an exposed lower level on the downhill side does not eat into the allowance. We confirm the cap, the datum and any pitch requirement before the elevation is fixed.
How much floor area does the stair actually take?
More than people budget for, and it comes out of both levels rather than one. Work it from the code numbers a Tennessee jurisdiction publishes. Knox County's own residential stair handout for the 2018 IRC gives a maximum riser of 7 3/4 inches and a minimum tread of 10 inches. A nine-foot floor-to-floor needs 14 risers at that maximum, so 13 treads at the minimum depth make a run of 10 ft 10 in before you add a landing at either end. At the 36-inch minimum clear width that is roughly 32 sq ft for the flight alone, and closer to 45 or 50 once the landings are in — on each level. Taller ground-floor ceilings, which is normally why someone wants this building type, make the run longer again. Local amendment can change the arithmetic: Loudon County raises the maximum riser to 8 inches and reduces the minimum tread to 9 inches, which pulls the same flight in to 9 ft 9 in, and it shifts the handrail trigger from four or more risers to a total rise of 30 inches or more.
Is a two-storey barndominium cheaper per square foot than a single-storey?
It depends entirely on what you hold constant, and that is the honest answer rather than a hedge. Compared with a single-storey building of the same footprint, adding a second storey is a real added cost: a stair, a floor system that has to span, taller walls, more wall area to insulate and finish, deeper footings and more engineering. Compared with a single-storey building of the same total finished area, the two-storey usually comes out ahead per square foot, because it needs roughly half the foundation and half the roof to deliver the same conditioned space. Both comparisons are legitimate. They answer different questions, and the one you are actually asking decides which number matters.
Do I need engineered drawings for a two-storey barndominium?
In practice, yes, and two Tennessee counties say so in their own words rather than leaving you to infer it from R301.1.3. Rutherford County's residential plans review list includes "pole barn type structures with living space regardless of square footage", and its footnote requires that drawings for pole barns or pre-manufactured steel structures intended for occupation "shall be design drawings prepared and sealed by a Tennessee Registered Architect or Engineer", labelled as designed to the edition the county has adopted; the county's published plans review fee is $200.00. Washington County answers its own frequently asked question with "Yes - Anywhere single family dwellings are allowed. Stamped drawings from a design professional are required for all alternative construction methods." Cumberland County requires blueprints by a registered design professional for two-storey homes and for any built-in basement. That is the same conclusion R301.1.3 reaches from the code side: a building whose structural elements exceed the limits of Section R301 is designed in accordance with accepted engineering practice, and a 40-foot clear-span floor plate is well outside those limits. We engage a Tennessee-licensed engineer for the structure and the seal.

Want this drawn for your program and your parcel? That is where a build actually starts.

Start your plans

Tell us what you want to build and we will draw this for your program, then confirm what it looks like on your parcel, the wind load it has to meet, and a realistic budget range. That conversation costs nothing.