A completed single-story barndominium with a long, low roofline and no upper-level windows.

1-Story Barndominium in Tennessee

A single-storey barndominium is the default version of this building type and the cheapest per square foot to get under roof. Post-frame and steel rigid-frame construction carries roof and wall load on widely spaced perimeter columns clear-spanning between them, and on one level that load path runs straight into the footings: one slab, one roof, no floor diaphragm in between, no stairwell taking area out of two levels, and no second-storey point load landing mid-span. What you trade for it is footprint, because the same finished area needs roughly twice the roof, twice the foundation and twice the graded pad. In Tennessee the good news is that the constraint most buyers brace for usually is not there — across the twenty jurisdictions researched for this site, only the City of Cleveland sets a minimum dwelling size. The constraint that does bite is appearance. A long four-sided rectangle under one shallow gable is what makes the building cheap, and it is exactly the shape a design standard in Knoxville's Estate Neighborhood district, or on a street-facing facade in Chattanooga, is written to catch.

What actually changes with this feature

The look is the easy part. These are the decisions that follow from it.

One load path, and no prescriptive second floor either

Roof and wall loads run through the frame, down the columns and into the footings, with one wall system and one foundation connection in between. A second storey adds a floor diaphragm those loads must transfer through, and puts residential floor live load onto columns sized for roof load alone. Staying on one level avoids the transfer entirely. It does not avoid engineering. IRC R301.1.1 lets a house be built to the prescriptive provisions of one of three standards — the AWC Wood Frame Construction Manual, AISI S230 for cold-formed steel framing, or ICC 400 for log structures — and a clear-span rigid frame or post-frame building matches none of them, so R301.1.3 applies and those elements are designed in accordance with accepted engineering practice. Those section numbers are stable across every edition of the residential code in force anywhere in Tennessee. The same rule reaches the floor and not only the roof: prescriptive floor-joist span tables run out around 23 to 25 feet even on their best rows, so a 40-foot clear span has no prescriptive dimensional-lumber second floor available to it in the first place.

Almost nowhere here sets a minimum house size

The rule that stops a compact single-storey plan in most of the country is a minimum heated floor area, and across the twenty Tennessee jurisdictions researched for this site it is very nearly absent. Maury, Jefferson, Robertson, Williamson, Rutherford, Wilson, Sumner, Bradley, Loudon, Sevier, Blount, Washington and Knox counties set none. Neither do Murfreesboro, Nashville and Davidson County, Memphis and Shelby County, Chattanooga and Hamilton County, Clarksville and Montgomery County, or Cookeville. Putnam County has no county zoning in its unincorporated area at all — no district to qualify for, no minimum lot size, no floor area. The single exception is the City of Cleveland, whose zoning ordinance requires a single-family dwelling to have a gross floor area of not less than 500 square feet of living space on a permanent foundation. Unincorporated Bradley County around it sets nothing, so the rule stops at the city limit.

The appearance standards a long low rectangle can fail

Two are worth naming and both are city rules with narrow scope. In the City of Knoxville, section 4.4.A.4 of the zoning code requires a primary structure in the EN district to satisfy two of three tests on roof form, number of finished floor levels and number of sides, and a single-storey rectangle under a shallow gable satisfies none of them. Knox County's A zone has no equivalent. In the City of Chattanooga, section 38-42(m) is a single sentence: windows, entrances, porches or other architectural features are required on all street-facing facades to avoid the appearance of blank walls. It reaches site-built single-unit detached dwellings inside the city, and Hamilton County has no equivalent. The two Chattanooga provisions that look far worse on a keyword search — a 4/12 minimum pitch and a limit on exterior materials — both sit inside manufactured-home rules and do not restrict a site-built house. Private covenants can be much harder than any of this: in Tellico Village, in Loudon County, the property owners' association handbook requires a minimum 4/12 pitch with at least six prominent roof planes, prohibits standing-seam and corrugated metal roofing, and lists permitted wall materials without metal on the list.

The form the Plateau market is already buying

Cumberland County has 21,750 residents aged 65 and over, which is 33.1% of its population and the highest share of any of Tennessee's 95 counties against a statewide 17.7%, and a median age of 53.6 that is also the highest in the state — US Census Bureau population estimates for 1 July 2024. Its 2024 components of change are 541 births against 1,106 deaths, a natural decrease, alongside net migration of positive 1,328: every bit of the county's growth is people moving in. A step-free entry, single-floor living and wide halls and doors are the parts of a house that are expensive or impossible to add afterwards, and Harvard's Joint Center for Housing Studies puts the share of existing US homes with all three at about 3.5%. Cumberland is also the least restrictive county we researched on form — no minimum floor area, no minimum roof pitch, no siding restriction and no required garage or porch in any instrument read — and the City of Crossville states that its zoning covers only the airport, floodplains, signs, mobile homes and mobile home parks.

A completed single-story barndominium with a long, low roofline and no upper-level windows.
Two of three, and a rectangle has none

Knoxville's Estate Neighborhood district asks a house to satisfy two of three tests. A single-storey rectangle with a 4/12 gable satisfies none of them.

Article 4, section 4.4.A.4 of the City of Knoxville zoning code requires primary structures to meet two of three requirements. First, a roof that is either flat at a pitch of less than 1/12 in a single plane, or steep at 6/12 or more, or articulated with multiple pitches, planes, ridge line directions or heights. Second, more than one finished floor level. Third, a habitable-and-attached-garage shape with no fewer than eight sides, counting only wall segments at least four feet long. One storey fails the second. Four walls fail the third. A 4/12 gable is neither flat, nor steep, nor articulated, so it fails the first as well. Scope matters here: this is a city standard, in the EN district only, and Knox County's A zone carries nothing like it. EN is the city's large-lot district at a 22,000 sq ft minimum, which is exactly why it is where a barndominium buyer inside the city lands. Every one of the three is buildable — a 6/12 pitch, a cross gable, a bumped-out wing — but they have to be in the drawings from the start. Section 4.4.A.6 also allows the section to be waived on irregular lots where planning staff determine the building site is not visible from the street.

Common ways to build this

Common configurations we see. Yours does not have to match one exactly — this is a starting point for the conversation, not a catalog.

All living, no shop bay

about 1,800 sq ft heated, whole footprint conditioned

The entire footprint is conditioned, which clears the only minimum dwelling size in the jurisdictions we work in — the City of Cleveland's 500 sq ft of living space — many times over. Three or four bedrooms across a single clear span with no interior wall carrying load, so the room layout can be revised without touching the structure. Two things decide whether it passes rather than the square footage: the massing, if the parcel is inside Knoxville's EN district or facing a Chattanooga street, and the foundation. Wilson County's section 3.12.04 requires a masonry, brick, stone or stucco curtain wall around the periphery of any principal dwelling whose finished floor sits above the surrounding grade — a slab-on-grade building whose floor is not above grade is outside that trigger, which is the ordinary single-storey case there.

Living plus attached shop under one roof

about 1,400 sq ft heated / about 1,000 sq ft shop

The common shape, and on one level attaching the shop rather than detaching it usually simplifies the zoning. An attached shop is part of the principal structure, so it is governed by the principal building's height limit and sidesteps the accessory-structure caps. Those caps are real: Knox County limits accessory buildings to 18 feet measured to the bottom chord of the truss rather than the ridge, which a 16-foot door plus header runs straight into; Nashville limits accessory structures on lots under 40,000 sq ft to one storey or sixteen feet; Washington County's R-1 district says the total floor area of all accessory structures may not exceed the area within the principal structure, while its A-1 and A-2 districts carry no equivalent cap. We confirm the attached reading with the county before it is relied on, because the districts differ.

Shop-forward, compact residence

about 1,200 sq ft heated / about 1,200 sq ft shop

An even split, with the residence folded in beside a serious workspace. With no minimum heated area in the counties above, the constraint moves to how the unheated half is measured. Maury County is the clearest illustration: the development tax there runs on floor area defined in Public Chapter 990 of 2024 as gross horizontal area that is heated or air-conditioned space, so an unheated shop bay under the same roof sits outside it, while the building permit fee is valued on everything under the roof including porches and decks. Two measurements of the same building, published by the same office. Where the shop is instead detached, Rutherford County caps the combined square footage of all accessory structures at 2,000 sq ft on a parcel of an acre or less, or 5% of lot area above an acre, with agricultural buildings exempt from the totals.

Single level built to be stayed in

about 2,000 sq ft heated, step-free throughout

One level is where step-free living is structural rather than retrofitted: a flat slab entry, wide doors, no stair and no lift shaft to frame. It is the form the demographics on the Cumberland Plateau are asking for, and Cumberland County places no restriction on it — no minimum size, no pitch rule, no cladding rule. Two local details shape the drawings anyway. Cumberland's own requirements sheet calls for a letter from an engineer for any wall above 10 feet tall, which a 12- or 14-foot sidewall triggers by itself. And where an in-law or guest wing is detached rather than attached it becomes an accessory dwelling with its own rules — Wilson County allows one detached accessory dwelling of up to 1,000 sq ft of heated area and one internal set of accessory quarters at 600 sq ft, one of each per property.

1-Story Barndominium: common questions

7 questions we get asked most often about this footprint. If yours is not on the list, ask it directly.

Is a single-storey barndominium cheaper to build than a two-storey one of the same size?
Per square foot, usually not, and the reason is worth understanding before you decide. Roof and foundation both scale with footprint rather than with finished area, and a single storey needs roughly twice the footprint for the same square footage. In NAHB's 2024 national cost-of-construction survey, foundation work accounted for 10.0% of total construction cost and framing and roof for 11.6% — about 21.6% between them, all of it footprint-driven. Split across two floors, that share per square foot falls. What comes back the other way is real too: no stair taking floor area out of both levels, no second-floor structural system, no taller wall assemblies or scaffolding, and one mechanical run instead of two. There is a local dimension as well, because the rules that key off footprint all land on the single-storey plan first — lot coverage caps, graded pad area, and Chattanooga's requirement of two exit doors on any dwelling with a footprint over 700 square feet. We do not publish a percentage for the net, because no barndominium-specific study segmented by storey count exists and the figures circulating online have no primary source behind them.
Does my Tennessee county set a minimum house size?
Almost certainly not, and this is the most useful thing we can tell someone drawing a modest single-level plan here. Of the twenty jurisdictions researched for this site, only one sets a minimum: the City of Cleveland, whose zoning ordinance requires a single-family dwelling to have not less than 500 square feet of living space on a permanent foundation. Maury, Jefferson, Robertson, Williamson, Rutherford, Wilson, Sumner, Bradley, Loudon, Sevier, Blount, Washington and Knox counties impose none; nor do Murfreesboro, Nashville, Memphis and Shelby County, Chattanooga and Hamilton County, Clarksville and Montgomery County, or Cookeville. Putnam County has no county zoning in the unincorporated area at all. Three square-footage figures in these ordinances get misreported as minimum house sizes and are not: Robertson County's 600 sq ft and Loudon County's 600 sq ft are both in the definition of a prefabricated dwelling and exist only to separate it from a mobile home, and Montgomery County's 480 sq ft sits in the mobile-home table and does not reach its agricultural or residential districts. The binding constraint on a small plan in these counties is the minimum lot, not the minimum house.
Can a single-storey plan be turned down for how it looks?
In two of our jurisdictions, yes, and in both cases it is a city rule with a defined scope rather than a county-wide one. The City of Knoxville's zoning code, section 4.4.A.4, requires a primary structure in the EN district to meet two of three requirements: a roof that is flat under a 1/12 pitch in one plane, or steep at 6/12 or more, or articulated; more than one finished floor level; or a shape with at least eight sides, counting wall segments of four feet or more. A single-storey rectangle with a 4/12 gable meets none of the three. It applies in that district and in that city only — Knox County's A zone has nothing comparable. The City of Chattanooga's section 38-42(m) requires windows, entrances, porches or other architectural features on all street-facing facades to avoid the appearance of blank walls, which is one sentence and applies to site-built detached dwellings inside the city; Hamilton County has no equivalent. Private covenants can be far stricter than either. Tellico Village in Loudon County requires a minimum 4/12 pitch with at least six prominent roof planes, prohibits standing-seam and corrugated metal roofing, and permits wall materials from a closed list that does not include metal panel — while the Loudon County zoning resolution itself sets no pitch, material or floor-area rule at all.
Will one level run into a lot coverage limit?
It is the configuration that reaches one first, since the whole building sits on the ground. The caps in our jurisdictions range widely and the district matters more than the county. Robertson County caps building coverage at 10% in AG-1, rising to 25% in AG-2 and 30% in RP-80; Maury County is 10% in its 15-acre agricultural district and 30% in its rural residential ones; Sumner County is 20% in AR, RP and RR and 25% in SR; Rutherford County is 20% for residential use in AR and RL and 25% in RM; the City of Knoxville's EN district is 25% building coverage with a separate 35% impervious cap; Knox County's A zone is 30% for main and accessory buildings combined; Wilson County's A-1 is 35%, with accessory structures separately limited to 20% of any rear yard; Murfreesboro's RS-15 is 35%; Cookeville's RS-20 and RS-15 are 40% including accessory buildings. The 10% figures read worse than they behave, because they sit on districts with fifteen-acre minimum lots. The ones that genuinely shape a wide building are the suburban caps on small lots — Murfreesboro's largest single-family district is 15,000 square feet, about a third of an acre. Sevier County adds a different constraint in its hillside and steep-slope overlays, where post-construction impervious area may not exceed 15% of the lot.
Does staying on one level mean I can skip the engineer?
No. IRC R301.1.1 allows a house to be built to the prescriptive provisions of one of three standards — the AWC Wood Frame Construction Manual, AISI S230 for cold-formed steel, or ICC 400 for log structures. A clear-span rigid frame or post-frame building matches none of them, so R301.1.3 applies and those elements are designed in accordance with accepted engineering practice. That is true on one level and on two, and it reaches the floor as well as the roof, because prescriptive floor-joist span tables stop around 23 to 25 feet. Three Tennessee jurisdictions say much the same thing in their own documents. Rutherford County's residential plans-review list names pole barn type structures with living space regardless of square footage and requires drawings sealed by a Tennessee registered architect or engineer. Washington County answers in its own FAQ that barndominiums are allowed anywhere single-family dwellings are, with stamped drawings from a design professional required for all alternative construction methods. Cumberland County's requirements sheet calls for a letter from an engineer for any wall above 10 feet tall and for footings or slabs on backfill. None of the three carves out an exception for a single storey. What one level buys you is a simpler thing to engineer, not a way around it.
Does going single-storey change the exits or the room layout?
It can, and two of our cities have written local amendments that land squarely on a long single-level plan. The City of Chattanooga replaced R311.2 so that dwellings with a footprint of more than 700 square feet must have at least two exit doors, each giving direct access from the habitable portions of the dwelling to the exterior without travelling through a garage; the model code requires one. Every barndominium exceeds 700 square feet of footprint, and on one storey the footprint is the whole house, so this applies to every plan in the city. The City of Murfreesboro added a section requiring that bedrooms not be the only means of access to other bedrooms or habitable spaces, and not serve as the only means of egress from other habitable spaces — directly relevant to the pass-through layouts common in stock barndominium plans, where rooms are strung along a single clear span. Both cities are on the 2018 edition of the residential code, which is where those section numbers belong. One more worth knowing on a shop-forward plan: Cumberland County states plainly in its own guidance that garage doors do not count as a means of escape, so a shop bay is not an egress route for the rooms behind it.
My land slopes. Is one level still the right call?
Often not, and this is where we would rather talk you out of it. A single storey needs the widest flat pad of any configuration, so on sloping ground it buys the most cut and fill, and the depth of cut at the uphill edge grows with the width of the building as well as its area. In Tennessee the cut is the problem: shallow limestone, solution cavities and sinkholes across the Valley and Ridge, and rock a foot down in places on the Cumberland Plateau, with depth to rock that can vary across a single footprint. Cumberland County's own sheet requires a slab to sit on undisturbed soil or on engineered backfill, calls for an engineer's letter for footings or slabs on backfill, and checks slope at the footing inspection at no more than 1 in 10. Septic is the other half of it and it is a state programme under TDEC rules rather than a county health department. Trench bottoms need four feet above rock, slope limits of 30% and 50% apply, and acceptable percolation is a band of 10 through 75 minutes per inch, so soil can fail for draining too fast as well as too slowly. TDEC's own soil tables flag the Crossville and Ramsey series as generally too shallow to bedrock for a septic system, and Crossville is the Cumberland County seat. Meanwhile the same slope costing you money is the condition a walkout basement wants. On genuinely flat ground the single-storey argument is strong; on a slope it is worth pricing against a walkout, and worth getting the soil evaluation done before the land is bought.

Want this drawn for your program and your parcel? That is where a build actually starts.

Start your plans

Tell us what you want to build and we will draw this for your program, then confirm what it looks like on your parcel, the wind load it has to meet, and a realistic budget range. That conversation costs nothing.